Power Adaptor - ACE-4520C-RS, 200W 24VDC ATX 1U / 2U Input Power Supply. CCL
Features
1. |
High efficiency |
2. | Low ripple & noise |
3. | Output overvoltage protection |
4. | Short circuit protection on all output |
5. | 100% burn-in under high ambient temperature (50°C) |
6. | Vacuum-impregnated transformer |
7. | MTBF: 100K hours at 25°C |
8. | 100% Hi-pot tested |
9. | Line input fuse protection |
20093585 | ACE-4520C-RS |
Specifications
Input | |||||||||||||||||||||||||
Input Voltage :18 ~ 36 VDC Input Input Current :15 A(RMS) @ -24 VDC Inrush Current :100 A Max for -24 VDC |
|||||||||||||||||||||||||
Output |
+3.3V- +5V- +12V total current not exceed 184W Overvoltage protection: +5 V output 5.7 V ~ 6.5 V +12 V output 13.1 V ~ 14.5 V +3.3 V output 3.7 V ~ 4.1 V Over Circuit protection: +5 V output 13.2 V ~ 18 V +12 V output 17.6 V ~ 24 V +3.3 V output 13.2 V ~ 18 V Short Circuit protection:+3.3 V- +5 V- +12 V Shut down and latch off |
||||||||||||||||||||||||
Output rise time | 20 ms Max. | ||||||||||||||||||||||||
Efficiency | 78% | ||||||||||||||||||||||||
MTBF | 100-000 hours on max load at +25 °C | ||||||||||||||||||||||||
Relative Humidity | 5 % ~ 95 % RH non-condensing | ||||||||||||||||||||||||
Output Connector | 20+4-pin ATX- 4-pin 12 V CPU- FDD- SATA and 2 x HDD | ||||||||||||||||||||||||
Storage Temperature | -20 °C~ 80 °C | ||||||||||||||||||||||||
Operation Temperature | 0 °C~ 50 °C | ||||||||||||||||||||||||